GT 8KW IGBT omvormer voor zonne-energie

Het merk: Lersion

De oorsprong van het product: China

De levering: 7-15 dagen

Het aanbod van: 100000

1 Duitse Infineon IGBT-module;
2 Amerika nieuwe generatie SAP-chiptechnologie;
3 50 ingenieurs R & D-teams, zelfontwerp en innovatiecircuit, systeem;
4 plus 12 jaar fabrieksfabrikantervaring, verbetering van feedback van klanten
* high end * veiliger * stabieler * lange levensduur

GT 8KW IGBT omvormer voor zonne-energie
Accu-overspanningsbeveiliging, accu-onderspanningsbeveiliging, overbelastingsbeveiliging,

ingebouwde zonnelaadregelaar (aanpassen)


Maximale laadstroom50A

  • 60A

  • 100A

  • 120A

  • Batterij voltage

  • 96V/192V

  • 96V/192V

  • 96V/192V

  • 96V/192V

  • PV-ingangsspanning

  • bereik


96V: 145V-230V; 192V: 260V-400V;Maximale PV-invoer96V: 4800W

solar inverter for homeinverter for off grid systemhybrid off grid solar invertersolar inverter for homeinverter for off grid systemhybrid off grid solar inverter
192V:9600W96V:5760W 192V:11520W96V:9600W 192V:19200W 96V:11520W



192V:23040WKoelmethodeVentilatoren koeling

solar inverter for home


milieu omstandighedenBedieningtemperatuur

-40(De levensduur van de batterij neemt af bij omgevingstemperaturen boven de 25 graden Celsius)Werking vochtigheid<95%(zonder te veroordelen)
Bedrijfshoogte<1000m (met een toename van 100m zal het de output met 1% verminderen) max5000mLawaai<58dB (afstand tot machine 1m)BeheerWeergaveLCD+LED

ComputercommunicatiekoppelRS232 (aanpassen)*De bovenstaande gegevens zijn ter referentie. Als er een verandering is, raadpleeg dan het echte object.5 LED kleuren touchscreen6 werkmodusMains 
Prioriteitsmodus (UPS)Stap 1: Als er netstroom is, wordt deze direct uitgevoerd door de netbypass en wordt tegelijkertijd de batterij opgeladen;Stap 2: Bij een plotselinge stroomuitval of een afwijking in het elektriciteitsnet, schakelt het systeem binnen 5 ms automatisch over op batterij-omvormervoeding om een ​​continue werking van de belasting te garanderen:Stap 3: Wanneer de netspanning is hersteld, schakelt het systeem automatisch over op netvoeding en laadt tegelijkertijd de batterij op; Uitleg: Als een fotovoltaïsch paneel is aangesloten, wordt bij normale fotovoltaïsche stroomopwekking ook de batterij opgeladen totdat deze volledig is opgeladen,
Batterijprioriteitsmodus (fotovoltaïsche prioriteit)Stap 1: Wanneer de batterijspanning normaal is, wordt het vermogen van de omvormer geleverd door de output van de batterij (batterij + fotovoltaïsche energie). Uitleg: Wanneer het vermogen van de fotovoltaïsche stroomopwekking groter is dan het elektriciteitsverbruik, zal het fotovoltaïsche vermogen rechtstreeks door de omvormer worden uitgevoerd voor de te gebruiken belasting en wordt de overtollige elektriciteit opgeslagen in de batterij; Als de fotovoltaïsche stroomopwekking niet aan de elektriciteitsvraag voldoet, zal het systeem batterijen gebruiken om een ​​deel van de elektriciteit aan te vullen om aan de elektriciteitsvraag te voldoenStap 2: Wanneer de batterij onder spanning staat, schakelt de voeding van de omvormer automatisch over naar de bypass-uitgangsvoeding van het lichtnet, maar de netvoeding laadt de batterij niet op; Uitleg: Onderspanning van de batterij geeft aan dat de fotovoltaïsche stroomopwekking niet voldoende is voor gebruik. Deze functie realiseert voornamelijk aanvullend opladen van stadselektriciteit en zorgt voor continu gebruik van elektrische apparatuur. Op dit moment moet de batterij worden opgeladen door zonne-energie.
Stap 3: Wanneer het fotovoltaïsche paneel of de netspanning wordt opgeladen tot de ingestelde waarde via de voeding van de omvormer, schakelt de voeding van de omvormer automatisch over naar de uitgang van de batterij-omvormer, waardoor prioriteit wordt gegeven aan het gebruik van fotovoltaïsche stroomopwekking.
Stap 4: Bij stroomuitval, onvoldoende fotovoltaïsche stroomopwekking en onvoldoende accuspanning schakelt de omvormer automatisch de uitgang uit en gaat in de slaapstand. Uitleg: Als de voeding op dit moment weer normaal wordt, wordt de voeding van de omvormer automatisch ingeschakeld en overgeschakeld naar de bypass-uitgang van de voeding; Als de netspanning niet terugkeert naar normaal, moet worden gewacht tot het fotovoltaïsche systeem de batterij oplaadt tot de ingestelde spanning en de omvormer automatisch wordt ingeschakeld en de uitvoer van de omvormer hervat (deze functie is een onbemande functie).
Energiebesparende modus (ECO)Wanneer de voeding van de omvormer in de energiebesparende modus staat, het inactieve verbruik rond de 3W-5W ligt en alleen de chip werkt, zal de voeding van de omvormer automatisch fietsen om het laadvermogen van het elektrische apparaat te detecteren. Wanneer het belastingsvermogen groter is dan 30 W, start het systeem automatisch op en gaat het binnen 5 seconden naar de normale werkmodus om de belasting van stroom te voorzien; Wanneer de belasting wordt gelost (minder dan 30 W), gaat deze automatisch binnen 5 seconden in de energiebesparende toestand; Deze functie vermindert onnodige stroomverspilling in het systeem aanzienlijk en minimaliseert het inactieve verbruik zoveel mogelijk.
Onbeheerd788592116130133150169
Wanneer de batterijcapaciteit onvoldoende is en de batterij onder spanning staat, schakelt de voeding van de omvormer de output uit en gaat automatisch in slaapstand. Het nullastverlies is ongeveer 1W. Wanneer het fotovoltaïsche systeem de accuspanning weer aanvult en terugkeert naar de ingestelde waarde, wordt de voeding van de omvormer automatisch ingeschakeld en wordt de uitgangsvoeding hervat. Beschrijving: Deze functie wordt voornamelijk toegepast op de gebruiksomgeving van pure off-grid zonne-energieopwekking zonder netstroom en langdurige onbemande werking.9097104132146149166185
(
zoals videobewaking en fotovoltaïsche waterpompen)
GT-serie8KW 
Verbindingsdiagram45Hz~65Hz
Output
Output voltageinverter mode:110VAC/220V±5%;AC mode:110VAC/220VAC±10%;
Frequency range
(AC mode)
Automatic tracking
Frequency range
(inverter mode)
50Hz/60Hz±1%
Over load capacityAC mode:(100%~110%:10min;110%~130%:1min;>130%:1s;)
inverter mode:(100%~110%:30s;110%~130%:10s;>130%:1s;)
Peak current ratio3:1max
Conversion time<10ms(Typical loads)
WaveformPure sine wave
Efficiency>95%(80% resistive loads)
Protection
functions
Battery overvoltage protection,battery undervoltage protection,overload protection,
short circuit protection,overtemperature protection,etc.
built in solar charge controller(adjust)
Max charge current50A60A100A120A
Battery voltage96V/192V96V/192V96V/192V96V/192V
PV input voltage
range
96V:145V-230V;192V:260V-400V;
Max PV input96V:4800W
192V:9600W
96V:5760W
192V:11520W
96V:9600W
192V:19200W
96V:11520W
192V:23040W
Cooling methodFans cooling
environmental conditions
Operating
temperature
0-40
Battery life decreases at ambient temperatures above 25 degrees Celsius
Operation humidity<95%without condesing)
Operating altitude<1000m(with increase of 100m,it will reduce output of 1%) max5000m
Noise<58dB(distance to machine 1m)
Management
DisplayLCD+LED
Computer
communication
interface
RS232(adjust)
*The above data is for reference. If there is any change, please refer to the real object.



5 LED Color Touch Screen

inverter for off grid system


6 Working Mode

  • Mains Priority Mode (UPS)

Step 1: When there is mains power, it is directly output by the mains bypass and simultaneously charges the battery;

Step 2: When there is a sudden power outage or abnormality in the mains, the system automatically switches to battery inverter power supply within 5ms to ensure continuous operation of the load:

Step 3: When the mains power is restored, the system automatically switches to mains power supply and charges the battery at the same time; Explanation: If a photovoltaic panel is connected, under normal photovoltaic power generation, the battery will also be charged until it is fully charged,

 

  • Battery priority mode (photovoltaic priority)

Step 1: When the battery voltage is normal, the inverter power will be supplied by the battery (battery+photovoltaic) inverter output. Explanation: When the photovoltaic power generation power is greater than the electricity consumption power, the photovoltaic power will be directly inverter output for the load to use, and the excess electricity will be stored in the battery; If the photovoltaic power generation does not meet the electricity demand, the system will use batteries to supplement some of the electricity to meet the electricity demand

Step 2: When the battery is under voltage, the inverter power supply will automatically switch to the mains bypass output power supply, but the mains will not charge the battery; Explanation: Under voltage of the battery indicates that the photovoltaic power generation is not sufficient for use. This function mainly achieves complementary charging of urban electricity and ensures continuous use of electrical equipment. At this time, the battery needs to be charged by solar energy.

Step 3: When the photovoltaic panel or mains power is charged to the set value through the inverter power supply, the inverter power supply will automatically switch to the battery inverter output, achieving priority use of photovoltaic power generation.

Step 4: When there is a power failure, insufficient photovoltaic power generation, and insufficient battery voltage, the inverter will automatically turn off the output and enter sleep mode. Explanation: If the power supply returns to normal at this time, the inverter power supply will automatically turn on and switch to the power supply bypass output; If the mains power does not return to normal, it is necessary to wait until the photovoltaic system charges the battery to the set voltage, and the inverter will automatically turn on and resume the inverter output (this function is an unmanned function).

 

  • Energy saving mode (ECO)

When the inverter power supply is in energy-saving mode, the idle consumption is around 3W-5W, and only the chip is working, the inverter power supply will automatically cycle to detect the load power of the electrical appliance. When the load power is greater than 30W, the system will automatically start up and enter normal working mode within 5S to supply power to the load; When the load is unloaded (less than 30W), it automatically enters the energy-saving state within 5s; This feature greatly reduces unnecessary power waste in the system and minimizes idle consumption as much as possible.


  • Unattended

When the battery capacity is insufficient and the battery is under voltage, the inverter power supply will turn off its output and automatically enter a sleep state. The no-load loss is about 1W. When the photovoltaic system replenishes the battery voltage and returns to the set value, the inverter power supply will automatically turn on and resume output power supply. Description: This function is mainly applied to the use environment of pure off grid solar power generation without mains power and long-term unmanned operation, (such as video monitoring and photovoltaic water pumps)


7 GT Series 8KW Connection Diagram


hybrid off grid solar inverter


solar inverter for home


bescherming tegen kortsluiting, bescherming tegen oververhitting, enz.

Factory display

Foshan-productiebasis
Onderzoek en innovatie op zonne-energie
Onderzoek en innovatie op zonne-energie
Zodra de Samenwerkingsdienst voor altijd
Zodra de Samenwerkingsdienst voor altijd
Gerelateerd product
Product Tag
Ontvang de laatste prijs? We reageren zo snel mogelijk (binnen 12 uur)